Architects’ and Engineers’ Guide to Cold-Formed Steel Framing Specifications

Home / Blog / Architects’ and Engineers’ Guide to Cold-Formed Steel Framing Specifications
steel stud installers-1920w

Cold-formed steel (CFS) framing has become essential in modern construction due to its structural efficiency, versatility, and sustainability. 

Architects and engineers use CFS in residential homes and large commercial projects due to its high strength-to-weight ratio, ease of installation, and consistent material properties. 

However, using it for your next drywall steel studs construction project requires professional guidance. So today, we’ll cover the technical details of CFS framing specifications, including the standards, materials, design considerations, and installation practices when using CFS.

Understanding Cold-Formed Steel Framing

Cold-formed steel refers to products shaped at room temperature by rolling or pressing. Cold-forming improves the material’s yield and tensile strength, which makes it ideal for structural frames.

  • The primary use in non-load-bearing and load-bearing wall systems, floors, roofs, and ceiling assemblies. 
  • Lightweight and high strength allow architects and engineers to design more complex and efficient structures. 

This is known for its corrosion resistance when adequately coated and can be prefabricated offsite for faster construction timelines.

Materials and Manufacturing Standards

CFS must meet stringent permission and standards to ensure consistency and performance. The most commonly used material standards include:

  • ASTM A1003. Specifies the metal sheets required to manufacture members. This standard covers coatings such as zinc (galvanized) or zinc-iron alloy (galvannealed), which protect the material from corrosion.
  • ASTM C955. Outlines the performance characteristics of load-bearing members, including requirements for the section properties, yield strength, and dimensional tolerances.
  • ASTM C645. Provides standards for non-load-bearing steel studs and track systems. It is often used in interior partitions.

Engineers and architects must ensure that the specified materials conform to these standards to guarantee structural integrity, corrosion resistance, and longevity in their projects.

Structural Properties and Section Design

Primarily designed as C-shaped sections (studs) and U-shaped channels (tracks), each with varying flange widths, web depths, and thicknesses depending on the application. The design of these sections follows strict guidelines to ensure that the members can resist the loads they are subjected to without buckling or yielding.

One of the most essential aspects of its design is the calculation of section properties, which include:

Moment of Inertia (I)

Essential for determining the member’s ability to resist bending. The larger the moment of inertia, the more resistant the member is to bending under load.

Section Modulus (S)

Used in the design of members subjected to bending. It is the ratio of the moment of inertia to the section’s extreme fibre from the neutral axis.

Radius of Gyration (r)

Helps determine a member’s susceptibility to buckling under axial loads. Members with a larger radius of gyration are less prone to buckling.

Yield Strength (Fy)

Depending on the material specification and the design requirements, yield strengths for CFS can range from 33 ksi to 50 ksi (230 MPa to 345 MPa).

Design Considerations for Architects and Engineers

The Canadian Standards Association (CSA) provides comprehensive design guidelines for cold-formed members through the CSA S136. Canada and the US use this specification, similar to the AISI S100.

CSA S136 covers axial, flexural (bending), local, distortional, and global buckling resistance. It standardizes structural design in Canada to ensure compliance with building codes and engineering practices.v

Load Conditions

  • Dead Loads: The weight of the structural elements like CFS framing, sheathing, and finishes must be considered when designing the structure.
  • Live Loads: These include variable loads such as occupants, furniture, and equipment, which the CFS must support without excessive deflection or failure.
  • Wind and Seismic Loads: Often used in areas where high wind or seismic activity is a concern. Engineers must ensure the framing can resist lateral forces without buckling or shear failure.

Thermal Expansion and Contraction

Like all materials, steel expands and contracts with temperature changes. Although metal’s thermal expansion coefficient is relatively low, accommodating these movements is necessary to prevent damage to finishes and structural elements.

Corrosion Protection

While cold-formed steel is naturally resistant to corrosion when coated with protective materials like galvanization, access to moisture, chemicals, or extreme environments can accelerate corrosion. 

  • Architects and engineers should specify appropriate coatings based on the project’s environment and design life expectancy. 
  • For most applications, a G40 or G60 zinc coating (as per ASTM A653) is sufficient to protect the metal.

Fire Resistance

Metal is non-combustible and is ideal for fire-rated assemblies. However, architects and engineers must consider the fire behaviour of insulation and finishes. The International Building Code (IBC) and the American Society for Testing and Materials (ASTM E119) provide standards for the fire-resistance ratings of various CFS assemblies.

Acoustic Performance

Acoustic performance is critical in many applications, particularly in multi-family residential buildings, hospitals, and schools. It can be designed with additional insulation and sound-dampening materials to meet specific Sound Transmission Class (STC) and Impact Insulation Class (IIC) ratings.

Installation and Construction Best Practices

Although the material is lightweight and easy to handle, improper installation can lead to performance issues such as deflection, buckling, or corrosion. Architects and engineers ensure that construction teams follow industry best practices for handling and installing.

Bracing and Bridging

Cold-formed metal studs must be braced to prevent lateral buckling, especially in tall wall assemblies. The most common types of bracing include lateral bracing, diagonal bracing, and bridging channels— all of which help distribute loads and improve the structure’s overall stability.

Fastening and Connection

The connections between CFS framing members are made using screws, bolts, or welds. 

  • Follow the manufacturer’s fastener type, spacing, and installation instructions. 
  • Improper fastening can lead to joint failure and compromise the system’s structural integrity. 

Panelization and Prefabrication

One significant advantage is its ability to be prefabricated offsite (the reason why some people can add to cart this material easily). This process, known as panelization, allows for greater precision and faster installation on-site. 

  • Prefabricated CFS panels can be custom-made to fit the exact dimensions of the project. This means waste reduction and lower labour costs. 
  • Engineers ensure that prefabricated panels meet the required design specifications and that all connections and bracing are adequately detailed.

Environmental and Sustainability Considerations

The iron used in CFS framing is made from recycled materials and is fully recyclable at the end of its lifecycle. 

  • Contributes to LEED (Leadership in Energy and Environmental Design) certification points, particularly in the categories of recycled content, regional materials, and innovation in design.
  • The lightweight nature reduces transportation costs and associated carbon emissions. Its durability ensures buildings have a long lifespan with minimal maintenance.
steel stud framing-1920

Work With Expert CFS Framing Installers 

Cold-formed steel framing offers architects and engineers a versatile, high-performance, and sustainable material for various construction projects. By understanding the material standards, structural properties, and design considerations, you can maximize the benefits of CFS in your upcoming projects.

Through careful specification and installation, steel stud installers from Vancouver Steel Stud Framing meet the rigorous demands of modern architecture and engineering. We provide a reliable solution for load-bearing and non-load-bearing applications.

Frequently Asked Questions

What are the differences between hot-rolled and cold-formed steel framing?

Cold-formed steel is shaped at room temperature, while hot-rolled steel is formed at high temperatures. 

  • Cold-formed offers higher strength-to-weight ratios, precision, and versatility for light applications. Suitable for load-bearing and non-load-bearing structures. 
  • Due to its higher thickness and load capacity, hot-rolled is best for heavier structural components like beams and columns.

What is the standard thickness range of these systems?

Framing members normally have a thickness range of 0.0346 inches (20 gauge) to 0.122 inches (12 gauge). The thickness is based on the structural loads the member will carry. Thicker gauges are used for load-bearing applications, while thinner gauges are suitable for non-load-bearing partitions.

What role do composite assemblies play in cold-formed framing?

Composite assemblies integrate metal framing with other materials (e.g. concrete, wood) to enhance structural performance. For example, composite floor systems combine cold-formed metal joists with concrete slabs to increase the floor’s load-bearing capacity and stiffness. This hybrid approach allows architects to utilize each material’s strengths, resulting in cost-effective, high-performance structures.